- Application: Flat roof – ballast mounting structure (non-invasive installation)
- Material: Aluminium + polyethylene
- Dimensions: 425 x 80 x 187 mm
Home
Popular Products
- Designed for fastening mounting rails to rafter elements on roofs covered with plain tiles (plain tile roof).
- Made of 2 mm thick stainless steel
- Dimensions: 240 x 150 mm
- The use of this hook does not require cutting or grinding roof tiles, which shortens installation time
Mounted to roof rafters
Adjustable 14 cm arm allows installation under various tiles
Pressed manufacturing ensures smooth edges
Installation requires wood screws (e.g., M8x120) and M10x20 bolts with nuts
Optional use of S-type support bracket
There are 21 products.
Active filters
- Protection class: TYPE 2
- Mounting method: 35 mm DIN mounting rail
- Rated operating voltage: 1000 V
- Max. current: 40 kA
- Protection rating: IP 20
- Operating temperature range: -30°C / +50°C
- Protection class: TYPE 1+2
- Mounting method: DIN rail 35 mm
- Rated voltage AC: 230 V
- Maximum continuous operating voltage AC: 275 V
- Degree of protection: IP 20
- Operating temperature range: -30°C / +50°C
- Protection class: TYPE 1+2
- Mounting method: DIN rail 35 mm
- Rated operating voltage: 1000 V
- Maximum operating voltage: 1060 V DC
- Degree of protection: IP20
- Operating temperature range: -30°C / +50°C
- Rated current: 32 A
- Number of poles: 2P
- Fuse link size: 10 x 38 mm
- Terminal capacity: 0.5–10 mm²
- Mounting method: DIN rail 35 mm
- Rated voltage (Un): 1000 V DC
- Number of modules: 2
- Number of strings: 2
- Current per string: 50 A
- Rated current: 30 mA
- String voltage: 300 ~ 1500 V DC
- Operating voltage: 100 V AC – 270 V AC
- Rated voltage: 230 V AC
- Degree of protection [IP]: IP66
- Protection class: II
- Rated current: 15 A
- Rated voltage: 1000 V DC
- Characteristic: time-delay (slow blow)
- Dimensions: 10 × 38 mm
- Operating temperature: -40 ~ +90 °C
- Standard: IEC60269
- Rated current: 16 A
- Rated voltage: 1000 V DC
- Characteristic: time-delay (slow blow)
- Dimensions: 10 × 38 mm
- Operating temperature: -40 ~ +90 °C
- Standard: IEC60269
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper