- Structural element for: metal roof tiles.
- Stainless steel double thread with a set of nuts and an EPDM gasket.
- Total length: 250 mm
- Screw depth: 80 mm
- Adapter dimensions: 80 x 30 x 4 mm
- Smooth transition between threads: 20 mm
Home
Popular Products
Mounted to roof rafters
Adjustable 14 cm arm allows installation under various tiles
Pressed manufacturing ensures smooth edges
Installation requires wood screws (e.g., M8x120) and M10x20 bolts with nuts
Optional use of S-type support bracket
- Width: 90 mm
- Material: Stainless steel
- Application: For mounting structures on standing seam metal roofs
There are 19 products.
Heating capacity: 12 kW
Type: Air-to-water, Split, 3-phase
Refrigerant: R410A
Max. water temperature: 57°C
Efficiency class: A+++ (SCOP up to 4.45)
Operating range: –25°C to +35°C
- Usable Module Capacity: 5 kWh
- Maximum Output Power: 2.5 kWh
- Nominal Voltage (Single-phase system): 360 V
- Operating Voltage Range (Single-phase system): 350-560 V
- Nominal Voltage (Three-phase system): 600 V
- Operating Voltage Range (Three-phase system): 600-980 V
- Protection Class: IP 65
- Operating Temperature: -10°C to 55°C
- Display: SOC status indicator, LED indicator
- Communication: RS485, CAN
- Power: 10,000 W
- Warranty: 10 years
- Efficiency: 97.90%
- Max DC voltage: 1000 V
- Start voltage: 250 V
- Voltage range: 270 - 480 V
- AC Voltage Range: 342VAC-440VAC
- Rated Voltage: 220VAC/230VAC
- Rated Frequency: 50Hz/60Hz
- Maximum Power: 3.3kVA
- Maximum Current: 15.2A
- Switching Time: <3s
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper

