- Length: 50 mm
- Hole: M8
- Material: aluminum
- Color: Black
Home
Popular Products
- Application: Flat roof – ballast mounting structure (non-invasive installation)
- Material: Aluminium + polyethylene
- Dimensions: 425 x 80 x 187 mm
There are 16 products.
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Quantity (x) / Conductor cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- A double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 6.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- A double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 6.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
Conductor cross-section: 6 mm²
Rated voltage: 600/1000 V
Operating temperature: –40°C to +90°C
UV and chemical resistance
Service life: up to 25 years
Outer diameter: 5.9 mm
Certificates: CE, TÜV, VDE