- Application: Flat roof – ballast mounting structure (non-invasive installation)
- Material: Aluminium + polyethylene
- Dimensions: 425 x 80 x 187 mm
Home
Popular Products
- Material: Stainless steel
- Dimensions [mm]: 230 x 30 x 4
- Suitable roof types: Bitumen shingles, roofing felt
- Mounting method: Screwed to decking / board
- Material: Stainless steel
- Dimensions [mm]: 190 x 30 x 4
- Suitable for: Roofs covered with bitumen shingles or roofing felt
- Mounting method: Screwed to roof decking / board
There are 15 products.
Heating capacity: 12 kW
Type: Air-to-water, Split, 3-phase
Refrigerant: R410A
Max. water temperature: 57°C
Efficiency class: A+++ (SCOP up to 4.45)
Operating range: –25°C to +35°C
✅ Maximum Power: 370 W
✅ Weight: 20.2 kg
✅ Dimensions: 1769 × 1052 × 30 mm
✅ Efficiency: 19.9%
✅ Temperature Coefficient: Pmax -0.35%/°C, Voc -0.27%/°C
✅ Frame: anodized aluminum, black
✅ Quantity per Pallet: 36 pcs
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Quantity (x) / Conductor cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- A double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 6.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper