Availability:
1399 In Stock
Home
Popular Products
Availability:
3101 In Stock
- Height: 30 mm
- Length: 50 mm
- Hole: M8
- Material: Aluminium
- Colour: Black
Availability:
192 In Stock
- Designed for fastening mounting rails to rafter elements on roofs covered with plain tiles (plain tile roof).
- Made of 2 mm thick stainless steel
- Dimensions: 240 x 150 mm
- The use of this hook does not require cutting or grinding roof tiles, which shortens installation time
There are 22 products.
Availability:
19 In Stock
- Protection class: TYPE 2
- Mounting method: 35 mm DIN mounting rail
- Rated operating voltage: 1000 V
- Max. current: 40 kA
- Protection rating: IP 20
- Operating temperature range: -30°C / +50°C
Availability:
41 In Stock
- Protection class: TYPE 1+2
- Mounting method: DIN rail 35 mm
- Rated voltage AC: 230 V
- Maximum continuous operating voltage AC: 275 V
- Degree of protection: IP 20
- Operating temperature range: -30°C / +50°C
Availability:
20 In Stock
- Protection class: TYPE 1+2
- Mounting method: DIN rail 35 mm
- Rated operating voltage: 1000 V
- Maximum operating voltage: 1060 V DC
- Degree of protection: IP20
- Operating temperature range: -30°C / +50°C
Availability:
183 In Stock
- Rated current: 32 A
- Number of poles: 2P
- Fuse link size: 10 x 38 mm
- Terminal capacity: 0.5–10 mm²
- Mounting method: DIN rail 35 mm
- Rated voltage (Un): 1000 V DC
- Number of modules: 2
Availability:
86 In Stock
- Rated current: 15 A
- Rated voltage: 1000 V DC
- Characteristic: time-delay (slow blow)
- Dimensions: 10 × 38 mm
- Operating temperature: -40 ~ +90 °C
- Standard: IEC60269
Availability:
98 In Stock
- Rated current: 16 A
- Rated voltage: 1000 V DC
- Characteristic: time-delay (slow blow)
- Dimensions: 10 × 38 mm
- Operating temperature: -40 ~ +90 °C
- Standard: IEC60269
Availability:
Out of stock
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
Availability:
Out of stock
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
Availability:
Out of stock
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
Availability:
140 In Stock
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
Availability:
4 In Stock
- Rated current: 32 A
- Cable cross-section: 2.5–6 mm²
- Rated voltage: 1000 V DC
- Test voltage: 6000 V (50 Hz, 1 minute)
- Operating temperature: -40 ~ +90 °C
- Protection rating: IP67
Availability:
Out of stock
- Quantity (x) / Conductor cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper

