- Structural element for: metal roof tiles.
- Stainless steel double thread with a set of nuts and an EPDM gasket.
- Total length: 250 mm
- Screw depth: 80 mm
- Adapter dimensions: 80 x 30 x 4 mm
- Smooth transition between threads: 20 mm
Home
Popular Products
- Material: Stainless steel
- Dimensions [mm]: 230 x 30 x 4
- Suitable roof types: Bitumen shingles, roofing felt
- Mounting method: Screwed to decking / board
- Application: Metal roof tiles (tile sheet roofing)
- Stainless steel double-thread screw with complete set of nuts and EPDM sealing washer
- Total length: 200 mm
- Threaded depth: 80 mm
- Smooth transition between threads: 20 mm
There are 24 products.
Active filters
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
✅ Number of strings: 2
✅ Number of poles: 4
✅ String voltage: 300–1500 V
✅ Current per string: 16–50 A
✅ Rated voltage: 100–270 V AC
✅ Operating voltage range: 230 V AC
✅ Rated current: 30 mA
✅ Switch-on (charging) current: avg. 100 mA
✅ Trip current: max 300 mA
✅ Feedback contact: 24 V DC – max 300 mA
✅ Operating temperature range: −20°C – +50°C
✅ Max operating temperature before automatic shutdown: +70°C
✅ Ambient temperature range: −40°C – +85°C
✅ Protection level: IP66
✅ Protection class: II
✅ Certifications: CE
✅ DC disconnect compliant with: EN 60947-1&3
✅ Number of operations: 10,000
✅ Number of operations under load (PV1): >1500
Conductor cross-section: 6 mm²
Rated voltage: 600/1000 V
Operating temperature: –40°C to +90°C
UV and chemical resistance
Service life: up to 25 years
Outer diameter: 5.9 mm
Certificates: CE, TÜV, VDE
UV, ozone, and weather resistant
High mechanical strength, abrasion resistant
Long service life: up to 25 years
Flame retardant per VDE 0482-332-2, DIN EN 60332-1
Operating temperature: –40°C to +90°C
Double insulation, copper conductor
Number of cores: 1
Conductor cross-section: 6 mm²
Conductor insulation: special PVC
Rated voltage: 600/1000 V
Temperature range: –40°C to +90°C (fixed and flexible)
Minimum bending radius: approx. 4 × cable Ø
Outer diameter: 5.9 mm
Conductor material: Cu – copper
Shielding: none
Number of cores: 1
Conductor cross-section: 6 mm²
Conductor insulation: special PVC
Rated voltage: 600/1000 V
Temperature range: –40°C to +90°C (fixed and flexible)
Minimum bending radius: approx. 4 × cable Ø
Outer diameter: 5.9 mm
Conductor material: Cu – copper
Shielding: none