- Structural element for: metal roof tiles.
- Stainless steel double thread with a set of nuts and an EPDM gasket.
- Total length: 300 mm
- Screw depth: 80 mm
- Adapter dimensions: 80 x 30 x 4 mm
- Smooth transition between threads: 20 mm
Home
Popular Products
Suitable for ceramic and concrete tiles
Dimensions: 500 x 30 x 5 mm
Material: stainless steel
- Application: Metal roof tiles (tile sheet roofing)
- Stainless steel double-thread screw with complete set of nuts and EPDM sealing washer
- Threaded depth: 80 mm
- Length: 300 mm
- Smooth transition between threads: 20 mm
There are 11 products.
- Maximum power: 500 W
- Efficiency: 22.5%
- Dimensions: 1961 × 1134 × 30 mm
- Weight: 26.5 kg
- Cell technology: N-Type mono
- Design: bifacial, dual glass
- Temperature coefficient: Pmax -0.29%/°C, Voc -0.28%/°C
- Open circuit voltage (Voc): 40.10 V
- Short circuit current (Isc): 15.86 A
- Frame thickness: 30 mm
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Maximum power: 440 W
- Efficiency: 22%
- Dimensions: 1762 x 1134 x 30 mm
- Weight: 21 kg
- Technology: N-Type i-TOPCon
- Module type: bifacial, double glass
- Temperature coefficient: Pmax -0.34%/°C, Voc -0.265%/°C
- Frame thickness: 30 mm
- Max fuse current: 25 A
- Maximum power: 440 W
- Efficiency: 22%
- Dimensions: 1762 x 1134 x 30 mm
- Weight: 21 kg
- Technology: N-Type i-TOPCon
- Module type: bifacial, double glass
- Temperature coefficient: Pmax -0.34%/°C, Voc -0.265%/°C
- Frame thickness: 30 mm
- Max fuse current: 25 A
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Quantity (x) / Conductor cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- A double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 6.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- A double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 6.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper