- Application: Metal roof tiles (tile sheet roofing)
- Stainless steel double-thread screw with complete set of nuts and EPDM sealing washer
- Total length: 250 mm
- Threaded depth: 80 mm
- Smooth transition between threads: 20 mm
Home
Popular Products
Mounted to roof rafters
Adjustable 14 cm arm allows installation under various tiles
Pressed manufacturing ensures smooth edges
Installation requires wood screws (e.g., M8x120) and M10x20 bolts with nuts
Optional use of S-type support bracket
There are 14 products.
Active filters
Heating capacity: 12 kW
Type: Air-to-water, Split, 3-phase
Refrigerant: R410A
Max. water temperature: 57°C
Efficiency class: A+++ (SCOP up to 4.45)
Operating range: –25°C to +35°C
- Power: 10,000 W
- Warranty: 10 years
- Efficiency: 97.90%
- Max DC voltage: 1000 V
- Start voltage: 250 V
- Voltage range: 270 - 480 V
✅ Maximum Power: 370 W
✅ Weight: 20.2 kg
✅ Dimensions: 1769 × 1052 × 30 mm
✅ Efficiency: 19.9%
✅ Temperature Coefficient: Pmax -0.35%/°C, Voc -0.27%/°C
✅ Frame: anodized aluminum, black
✅ Quantity per Pallet: 36 pcs
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 6.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Quantity (x) / Conductor cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Double-insulated single-core cable with electron-beam crosslinked insulation, designed for photovoltaic installations.
- Quantity (x) / Cross-section: 1 x 4.0 mm²
- Outer diameter of the cable: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper