- Structural element for: metal roof tiles.
- Stainless steel double thread with a set of nuts and an EPDM gasket.
- Total length: 300 mm
- Screw depth: 80 mm
- Adapter dimensions: 80 x 30 x 4 mm
- Smooth transition between threads: 20 mm
Home
Popular Products
- Application: Flat roof – ballast mounting structure (non-invasive installation)
- Material: Aluminium + polyethylene
- Dimensions: 425 x 80 x 395 mm
- Application: Metal roof tiles (tile sheet roofing)
- Stainless steel double-thread screw with complete set of nuts and EPDM sealing washer
- Threaded depth: 80 mm
- Length: 300 mm
- Smooth transition between threads: 20 mm
There are 11 products.
Active filters
- Usable Module Capacity: 5 kWh
- Maximum Output Power: 2.5 kWh
- Nominal Voltage (Single-phase system): 360 V
- Operating Voltage Range (Single-phase system): 350-560 V
- Nominal Voltage (Three-phase system): 600 V
- Operating Voltage Range (Three-phase system): 600-980 V
- Protection Class: IP 65
- Operating Temperature: -10°C to 55°C
- Display: SOC status indicator, LED indicator
- Communication: RS485, CAN
- AC Voltage Range: 342VAC-440VAC
- Rated Voltage: 220VAC/230VAC
- Rated Frequency: 50Hz/60Hz
- Maximum Power: 3.3kVA
- Maximum Current: 15.2A
- Switching Time: <3s
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
- Power [W]: 700
- Maximum efficiency [%]: 99.6
- Maximum voltage [V]: 80
- Maximum MPPT voltage [V]: 80
- Minimum MPPT voltage [V]: 16
- Maximum current [A]: 15
- Dimensions [mm]: 138.4 × 139.7 × 22.9
- Communication type: WiFi
Conductor cross-section: 6 mm²
Rated voltage: 600/1000 V
Operating temperature: –40°C to +90°C
UV and chemical resistance
Service life: up to 25 years
Outer diameter: 5.9 mm
Certificates: CE, TÜV, VDE
UV, ozone, and weather resistant
High mechanical strength, abrasion resistant
Long service life: up to 25 years
Flame retardant per VDE 0482-332-2, DIN EN 60332-1
Operating temperature: –40°C to +90°C
Double insulation, copper conductor
Number of cores: 1
Conductor cross-section: 6 mm²
Conductor insulation: special PVC
Rated voltage: 600/1000 V
Temperature range: –40°C to +90°C (fixed and flexible)
Minimum bending radius: approx. 4 × cable Ø
Outer diameter: 5.9 mm
Conductor material: Cu – copper
Shielding: none
Number of cores: 1
Conductor cross-section: 6 mm²
Conductor insulation: special PVC
Rated voltage: 600/1000 V
Temperature range: –40°C to +90°C (fixed and flexible)
Minimum bending radius: approx. 4 × cable Ø
Outer diameter: 5.9 mm
Conductor material: Cu – copper
Shielding: none