- Application: Metal roof tiles (tile sheet roofing)
- Stainless steel double-thread screw with complete set of nuts and EPDM sealing washer
- Total length: 250 mm
- Threaded depth: 80 mm
- Smooth transition between threads: 20 mm
Home
Popular Products
- Width: 90 mm
- Material: Stainless steel
- Application: For mounting structures on standing seam metal roofs
- Structural element for: metal roof tiles.
- Stainless steel double thread with a set of nuts and an EPDM gasket.
- Total length: 250 mm
- Screw depth: 80 mm
- Adapter dimensions: 80 x 30 x 4 mm
- Smooth transition between threads: 20 mm
There are 37 products.
Active filters
- Rated current: 15 A
- Rated voltage: 1000 V DC
- Characteristic: time-delay (slow blow)
- Dimensions: 10 × 38 mm
- Operating temperature: -40 ~ +90 °C
- Standard: IEC60269
- Number of strings: 4
- Number of poles: 8
- Maximum voltage per string (Vdc): 1500
- Maximum current per string (A): 25
- Operating voltage: 100Vac~270Vac
- Operating temperature range: -20°C – +50°C
- Rated current: 16 A
- Rated voltage: 1000 V DC
- Characteristic: time-delay (slow blow)
- Dimensions: 10 × 38 mm
- Operating temperature: -40 ~ +90 °C
- Standard: IEC60269
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
-
Maximum efficiency: 97.4%
-
Maximum recommended DC power: 3900 W
-
Rated output power: 3000 W
-
Maximum DC voltage: 600 V
-
Start-up voltage: 120 V
-
MPPT voltage range: 80–550 V DC
-
Number of MPPTs: 2
-
Number of MPPT inputs: 1+1
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
✅ Number of strings: 2
✅ Number of poles: 4
✅ String voltage: 300–1500 V
✅ Current per string: 16–50 A
✅ Rated voltage: 100–270 V AC
✅ Operating voltage range: 230 V AC
✅ Rated current: 30 mA
✅ Switch-on (charging) current: avg. 100 mA
✅ Trip current: max 300 mA
✅ Feedback contact: 24 V DC – max 300 mA
✅ Operating temperature range: −20°C – +50°C
✅ Max operating temperature before automatic shutdown: +70°C
✅ Ambient temperature range: −40°C – +85°C
✅ Protection level: IP66
✅ Protection class: II
✅ Certifications: CE
✅ DC disconnect compliant with: EN 60947-1&3
✅ Number of operations: 10,000
✅ Number of operations under load (PV1): >1500
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper