- Length: 50 mm
- Hole: M8
- Material: aluminum
- Color: Black
Home
Popular Products
- Material: Stainless steel
- Dimensions [mm]: 230 x 30 x 4
- Suitable roof types: Bitumen shingles, roofing felt
- Mounting method: Screwed to decking / board
- Structural element for: metal roof tiles.
- Stainless steel double thread with a set of nuts and an EPDM gasket.
- Total length: 300 mm
- Screw depth: 80 mm
- Adapter dimensions: 80 x 30 x 4 mm
- Smooth transition between threads: 20 mm
There are 26 products.
Active filters
Number of strings: 4
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 6
Current per string: up to 55 A
Rated current: 30 mA
Chain voltage: 300–1500 V DC
Operating voltage: 100–270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
Number of strings: 3
Current per string: 50 A
Rated current: 30 mA
Chain voltage: 300 – 1500 V DC
Operating voltage: 100 – 270 V AC
Rated voltage: 230 V AC
Protection rating: IP66
Protection class: II
✅ Number of strings: 2
✅ Number of poles: 4
✅ String voltage: 300–1500 V
✅ Current per string: 16–50 A
✅ Rated voltage: 100–270 V AC
✅ Operating voltage range: 230 V AC
✅ Rated current: 30 mA
✅ Switch-on (charging) current: avg. 100 mA
✅ Trip current: max 300 mA
✅ Feedback contact: 24 V DC – max 300 mA
✅ Operating temperature range: −20°C – +50°C
✅ Max operating temperature before automatic shutdown: +70°C
✅ Ambient temperature range: −40°C – +85°C
✅ Protection level: IP66
✅ Protection class: II
✅ Certifications: CE
✅ DC disconnect compliant with: EN 60947-1&3
✅ Number of operations: 10,000
✅ Number of operations under load (PV1): >1500
- Maximum power: 420 W
- Weight: 22 kg
- Dimensions: 1722 × 1134 × 30 mm
- Efficiency: 21.52%
- Temperature coefficient: Pmax -0.29%/°C, Voc -0.25%/°C
- Frame: black, full black
- Frame thickness: 30 mm
- Quantity per pallet: 36 pieces
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper

