- Application: Flat roof – ballast mounting structure (non-invasive installation)
- Material: Aluminium + polyethylene
- Dimensions: 425 x 80 x 395 mm
Home
Popular Products
Mounted to roof rafters
Adjustable 14 cm arm allows installation under various tiles
Pressed manufacturing ensures smooth edges
Installation requires wood screws (e.g., M8x120) and M10x20 bolts with nuts
Optional use of S-type support bracket
- Designed for fastening mounting rails to rafter elements on roofs covered with plain tiles (plain tile roof).
- Made of 2 mm thick stainless steel
- Dimensions: 240 x 150 mm
- The use of this hook does not require cutting or grinding roof tiles, which shortens installation time
There are 7 products.
Active filters
- Power: 10,000 W
- Warranty: 10 years
- Efficiency: 97.90%
- Max DC voltage: 1000 V
- Start voltage: 250 V
- Voltage range: 270 - 480 V
- Number of strings: 2
- Current per string: 50 A
- Rated current: 30 mA
- String voltage: 300 ~ 1500 V DC
- Operating voltage: 100 V AC – 270 V AC
- Rated voltage: 230 V AC
- Degree of protection [IP]: IP66
- Protection class: II
-
Inverter power: 10 kW
-
Type: 3-phase hybrid inverter All-in-One
-
Battery capacity: 15 kWh (3 × 5 kWh)
-
Expandable battery capacity: up to 25 kWh
-
PV oversizing: up to 150%
-
AC overload: up to 110%
-
UPS/backup switching time: ≤10 ms
-
Max PV string current: 16 A
-
Protection rating: IP65
-
Installation: indoor or outdoor
-
Communication: communication module included
-
EV compatibility: yes (SAJ EV-Ready)
- Double-insulated single-core cable with electron-beam cross-linked insulation for photovoltaic installations
- Quantity / Cable cross-section: 1 x 4.0 mm²
- Outer diameter: 5.5 mm
- Rated voltage: 1500 V DC
- Test voltage: 6.5 kV AC
- Type of conductor: Stranded, tinned copper
Conductor cross-section: 6 mm²
Rated voltage: 600/1000 V
Operating temperature: –40°C to +90°C
UV and chemical resistance
Service life: up to 25 years
Outer diameter: 5.9 mm
Certificates: CE, TÜV, VDE
Number of cores: 1
Conductor cross-section: 6 mm²
Conductor insulation: special PVC
Rated voltage: 600/1000 V
Temperature range: –40°C to +90°C (fixed and flexible)
Minimum bending radius: approx. 4 × cable Ø
Outer diameter: 5.9 mm
Conductor material: Cu – copper
Shielding: none
Number of cores: 1
Conductor cross-section: 6 mm²
Conductor insulation: special PVC
Rated voltage: 600/1000 V
Temperature range: –40°C to +90°C (fixed and flexible)
Minimum bending radius: approx. 4 × cable Ø
Outer diameter: 5.9 mm
Conductor material: Cu – copper
Shielding: none